What it does: calculates reactions, bending-moment/shear/axial-force and deflection diagrams, checks strength (von Mises) and buckling, and suggests the minimum steel/aluminum profile needed (IPE/HEA/HEB/HEM/UPN).
How to use it:
1. Set the beam length and material in "Beam geometry" and "Design".
2. Add supports in "Supports" — fixed, pinned or roller, with their position.
3. Add loads in "Loads" — point loads, moments or distributed loads, with their position and magnitude.
4. Check the diagrams and results on the right; the badge above the beam drawing warns if the support combination is not solvable (statically determinate).
Sign convention: the origin (x=0) is at the left end of the beam. The Y axis points upward, so a hanging weight or gravity load is entered with a negative sign. Positive moments rotate counter-clockwise.
Scope: single-span statically determinate beams only (simply supported, cantilevers, or combinations with exactly 3 restraints in total) — does not cover continuous multi-support beams, tubular sections, fatigue or dynamic loads.
A preliminary-sizing support tool — it does not replace a calculation signed off by a competent engineer. Back to Tools ↗
Lcr (buckling length, weak axis z-z) is used ONLY if the beam is in compression somewhere along its length (N>0 in this tool's convention). By default L = beam length is proposed (equivalent to pinned-pinned, β=1, the usual worst case). If the ends are actually braced/fixed against lateral buckling, enter β·L instead (e.g. 0.7·L pinned-fixed, 0.5·L fixed-fixed, 2·L for a cantilever) — this tool does NOT infer the degree of buckling fixity from the bending-support restraints, since they don't necessarily match (bracing, gusset plates, etc. are unrelated to the bending-support model).
Right-handed reference system: origin (x=0) at the LEFT end of the beam, x positive to the right, y positive UPWARD. The beam occupies x∈[0, L]. Supports and loads can be placed freely within that range.
N (axial force) convention: in this tool N>0 means COMPRESSION and N<0 means TENSION (verified numerically against the calculation engine) — this is the opposite of the tension-positive convention used in some textbooks. The buckling check uses this same convention.
Check the restraints for each support: Rx (horizontal), Ry (vertical), Mz (rotation, counter-clockwise+). Each support also has a vertical eccentricity e (mm, +upward from the neutral axis): if that support has Rx checked, the horizontal reaction applied at that offset generates a local moment −Rx·e. For the system to be statically determinate: exactly 1 support with Rx, and exactly 2 restraints in total between Ry/Mz (e.g. 2 supports with Ry = simply supported, or 1 support with Ry+Mz = fixed/cantilever).
Convention: Fy and q positive = UPWARD (a typical gravity load is entered as NEGATIVE). M0 positive = counter-clockwise (right-hand rule). Types: Point (Fx,Fy, eccentricity e → moment M=−Fx·e), Point moment (direct M0), Distributed (uniform or trapezoidal, qa→qb in N/mm). Add as many of each type as you need.
Fifth diagram "Required profile by segment": which catalog profile is needed at each section, combining M+V+N. Sixth diagram "σeq(x)": the von Mises equivalent stress of the already selected profile along the whole beam, compared to the allowable — to see at a glance where you have more or less real margin, not just at the critical section.
Self-weight (converged):
Combined check (von Mises, critical section):
Critical section (where σeq above was calculated — doesn't always match the |M| max section):
Flexural buckling, weak axis z-z (EN1993-1-1 §6.3.1.1 — only if there is compression, N>0 at some point; does not include lateral-torsional buckling or M+N interaction):
Reactions:
Reference: 1 N·mm = 10⁻³ N·m = 10⁻⁶ kN·m
δ_real = (δ/EI) · E · Iy of the selected profile.
Wy in mm³ (tables converted from cm³×10³).