Choosing the right material for a cryogenic component is not an intuitive decision. Many materials that perform well at room temperature become brittle below 80 K, and differential thermal contractions between materials can generate stresses sufficient to fracture joints or jam mechanisms.
Ashby's methodology
The process followed Ashby's performance index methodology: for each component function and constraint, a dimensionless index is derived that combines the relevant material properties. CES Edupack selection charts allow these index lines to be superimposed and the material space to be filtered objectively.
For cryogenic structural components, the key properties are: Young's modulus at low temperature, ductile-to-brittle transition temperature (absent in FCC metals such as aluminium and austenitic steel), thermal expansion coefficient and thermal conductivity (which determines cooling rate and thermal gradients within the component).
Application to the HARMONI project
Selection results were applied directly to the structural components of the test bench and the Pupil Mask Rotator, confirming that 6061 aluminium was the optimum choice for the base plate and that Ti-6Al-4V titanium offered the best stiffness-to-thermal-expansion ratio for precision elements.